#NGMP Portable Configurable parameters
#TODO:  defaultValue, Limits strings are actually indices into the language manager table
# name				|value	|default			|Constraint	|limits
# name				|value	|default			|Constraint	|LclName|limits
#
#
version				|		|4					|ecRange	|					|1:99
language			|		|					|ecStrings	|_2				|		# Special:  limits are ..\Language\*.txt
measMode			|		|_100				|ecStrings	|_99				|_100		:_101		:_102			# Press To Read:Interval:Continuous
measDuration		|		|8 h				|ecStrings	|_104				|15 min:30 min:1 h:4 h:8 h:24 h:48 h:_82				
transferMode		|		|_584				|ecStrings	|_581				|_584			:_585		:_586		 #Method transfer Store data:Import:Export
measInterval		|		|15 min				|ecStrings	|_106				|10 s:30 s:1 min:5 min:15 min:30 min
accessControl		|		|_30				|ecStrings	|_111			|_29:_30	# off, on
password			|		|					|ecString	|_112				|12
enteredPassword		|		|					|ecString	|_136				|12		# psuedo-entry - used for user entry
contrast			|		|5					|ecRange	|_116				|0:9
autoshutoff			|		|10 min				|ecStrings	|_118				|1 min:2 min:5 min:10 min:30 min:1 h:2 h:_120	
autoshutoffCal		|		|30 min				|ecStrings	|_118				|1 min:2 min:5 min:10 min:30 min:1 h:2 h:_120	
backlight			|		|1 min				|ecStrings	|_119				|10 s:20 s:30 s:1 min:2 min:5 min:10 min:_120	
displayMode			|		|_31				|ecStrings	|_33				|_31		:_32	
sound				|		|7					|ecOption	|_121				|_122		:_123			:_124				#:_125		
dateTimeformat		|		|dd-mmm-yyyy 24h	|ecStrings	|					|mm/dd/yyyy 12h:mm/dd/yyyy 24h:dd-mm-yyyy 12h:dd-mm-yyyy 24h:yyyy-mm-dd 12h:yyyy-mm-dd 24h:dd-mmm-yyyy 12h:dd-mmm-yyyy 24h
reportType			|		|_196				|ecStrings	|_224			|_196	:_197		:_198		# Basic, Advanced, Total
columnHeader		|		|_29				|ecStrings	|_225				|_29:_30
tempUnits			|		|C					|ecStrings	|_134				|C:F
deferChk			|		|15 min				|ecStrings	|_89				|5 min:10 min:15 min:30 min:60 min
usbDeviceType		|		|_147				|ecStrings  |_131				|_147			:_146		
#
operator			|		|_167			|ecStrings	|_161			|_167	
hideoperatorAdd		|		|					|ecString	|_163				|12
hideoperatorDel		|		|					|ecStrings	|_165				|
sampleid			|		|_167			|ecStrings	|_169				|_167	
hidesampleidAdd		|		|					|ecString	|_171				|12
hidesampleidDel		|		|					|ecStrings	|_173				|
#
# non-configurable parameters
#
logLevel			|		|1					|ecRange	|_6				|1:5	# matches e_LogFilterLevel
subdelimiter		|:		|:					|ecString	|_6				|1		# limits, Screens & Options field delimiter
headerSent			|		|_21				|ecStrings	|_6				|_21:_22
internalDataStore	|		|_29				|ecStrings	|					|_29:_30	# off, on
checkStringLength	|		|Off				|ecOption	|					|On:Off
#ck 